<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>prova di carico &#8211; Indagini strutturali</title>
	<atom:link href="https://www.structuralsurveys.it/tag/prova-di-carico/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.structuralsurveys.it</link>
	<description>Diagnostica e monitoraggio del costruito</description>
	<lastBuildDate>Mon, 03 Aug 2026 12:27:48 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://www.structuralsurveys.it/wp-content/uploads/2019/12/cropped-favicon-32x32.png</url>
	<title>prova di carico &#8211; Indagini strutturali</title>
	<link>https://www.structuralsurveys.it</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">170619051</site>	<item>
		<title>Museo della Calzatura</title>
		<link>https://www.structuralsurveys.it/lavori/verifica-statica-di-un-solaio-ligneo/</link>
					<comments>https://www.structuralsurveys.it/lavori/verifica-statica-di-un-solaio-ligneo/#comments</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Sun, 03 Apr 2016 14:55:02 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/20/harnessing-the-power-of-vr-with-power-rangers-and-snapdragon-835/</guid>

					<description><![CDATA[Il complesso architettonico secentesco di Villa Foscarini Rossi si trova a Stra, fra Padova e Venezia, lungo le rive del fiume Brenta. La Villa Padronale ospita il Museo Rossimoda della Calzatura, mentre la Foresteria, con il suo elegante Salone degli Affreschi, é adibita a centro congressi.]]></description>
										<content:encoded><![CDATA[<p>Il complesso architettonico secentesco di Villa Foscarini Rossi si trova a Stra (VE), lungo le rive del fiume Brenta. La Villa Padronale ospita il Museo Rossimoda della Calzatura — che raccoglie una collezione di oltre 1500 modelli di calzature femminili di lusso frutto di collaborazioni con i marchi più prestigiosi — mentre la Foresteria è adibita a centro congressi.</p>
<p><span id="more-61"></span></p>
<p>Il committente ha richiesto la verifica statica del solaio del primo piano per un carico distribuito di 350 kg/m². La struttura portante è caratterizzata da un’orditura principale costituita da travi lignee a sezione squadrata con un interasse di circa 35 cm.Considerando il comportamento del solaio come schema di trave appoggiata-appoggiata e impostando l’equivalenza dei momenti massimi tra la porzione di solaio totalmente caricata e quella parzialmente caricata, il carico equivalente <strong>q<sub>t</sub></strong> da applicare mediante serbatoio è stato calcolato con la seguente relazione:</p>
<div data-path-to-node="6,8"></div>
<p style="text-align: center;"><strong>q<sub>t</sub>=qL<sup>2</sup>/(2Lb-b<sup>2</sup>)</strong></p>
<p data-path-to-node="6,9"><i data-path-to-node="6,9" data-index-in-node="0">Dove:</i></p>
<ul data-path-to-node="6,10">
<li>
<p data-path-to-node="6,10,0,0"><span class="math-inline" data-math="q_t" data-index-in-node="0"><strong>q<sub>t</sub></strong></span> è il carico effettivo da applicare sulla superficie della piscina;</p>
</li>
<li>
<p data-path-to-node="6,10,1,0"><strong><span class="math-inline" data-math="q" data-index-in-node="0">q</span></strong> è il carico di progetto (350 kg/m²);</p>
</li>
<li>
<p data-path-to-node="6,10,2,0"><strong><span class="math-inline" data-math="L" data-index-in-node="0">L</span></strong> è la luce netta del solaio;</p>
</li>
<li>
<p data-path-to-node="6,10,3,0"><strong><span class="math-inline" data-math="b" data-index-in-node="0">b</span></strong> è la lunghezza della piscina di carico.</p>
</li>
</ul>
<p>Pertanto, il carico teorico distribuito di 350 kg/m² corrisponde a un carico effettivo sulla superficie d&#8217;impronta pari a 390 kg/m², equivalente a un volume di 3.276 litri d’acqua. La quantità d’acqua è stata poi incrementata fino a 3.600 litri (circa il 10% in più) per tenere conto della collaborazione trasversale delle travi adiacenti.</p>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2016/04/Carico_deformazioni-2.jpg'><img decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Carico_deformazioni-2-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico ad acqua" srcset="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Carico_deformazioni-2-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2016/04/Carico_deformazioni-2-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2016/04/Trend_deformazioni-2.jpg'><img decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Trend_deformazioni-2-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico ad acqua" srcset="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Trend_deformazioni-2-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2016/04/Trend_deformazioni-2-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2016/04/Prova_di_carico_acqua-2.jpg'><img decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Prova_di_carico_acqua-2-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico ad acqua" srcset="https://www.structuralsurveys.it/wp-content/uploads/2016/04/Prova_di_carico_acqua-2-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2016/04/Prova_di_carico_acqua-2-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

<p data-path-to-node="6,13">Per la sollecitazione del solaio è stata impiegata una piscina in PVC di dimensioni <span class="math-inline" data-math="4,00 \times 2,10\text{ m}" data-index-in-node="84">4,00 X 2,10 m</span> (superficie in pianta di <span class="math-inline" data-math="8,4\text{ m}^2" data-index-in-node="135">8,4 m²</span>).</p>
<p data-path-to-node="6,14">Il monitoraggio dei movimenti verticali (cedimenti/freccia) è avvenuto mediante il posizionamento di tre sensori di spostamento (trasduttori):</p>
<ul data-path-to-node="6,15">
<li>
<p data-path-to-node="6,15,0,0"><b data-path-to-node="6,15,0,0" data-index-in-node="0">1° sensore:</b> posizionato in mezzeria della trave maggiormente sollecitata;</p>
</li>
<li>
<p data-path-to-node="6,15,1,0"><b data-path-to-node="6,15,1,0" data-index-in-node="0">2° sensore:</b> posizionato in corrispondenza dell&#8217;appoggio;</p>
</li>
<li>
<p data-path-to-node="6,15,2,0"><b data-path-to-node="6,15,2,0" data-index-in-node="0">3° sensore:</b> posizionato lateralmente per valutare la collaborazione trasversale del solaio.</p>
</li>
</ul>
]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/verifica-statica-di-un-solaio-ligneo/feed/</wfw:commentRss>
			<slash:comments>2</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">61</post-id>	</item>
		<item>
		<title>Ospedale Civile Padova</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-a-spinta-padova/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-a-spinta-padova/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Thu, 19 Nov 2015 15:55:06 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/19/so-you-want-to-be-a-startup-investor-here-are-things-you-should-know/</guid>

					<description><![CDATA[Su incarico di una società di Roma, nel mese di novembre 2015 è stata eseguita una prova di carico statico su un solaio in latero cemento, presso Laboratorio analisi urgenze dell’Azienda Ospedaliera di Padova.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="8,3">1. Inquadramento e Finalità dell&#8217;Indagine</h3>
<p data-path-to-node="8,4">Su incarico di una società d&#8217;ingegneria di Roma, nel mese di novembre 2015 è stata condotta una prova di carico statico su un solaio in latero-cemento situato presso il Laboratorio Analisi Urgenze dell’Azienda Ospedaliera di Padova.</p>
<p data-path-to-node="8,5">Le operazioni di prova sono state eseguite da operatori accreditati e certificati da RINA S.p.A. (organismo accreditato ACCREDIA) di <span class="math-inline" data-math="III^\circ" data-index-in-node="133">III°</span> Livello per l&#8217;esecuzione di Prove Non Distruttive (PND) su strutture in c.a., c.a.p. e muratura, in conformità alla norma UNI EN ISO 9712.</p>
<p data-path-to-node="8,6">L&#8217;indagine è stata richiesta per la verifica della risposta statica e deformativa del solaio del piano rialzato, avente una luce netta di calcolo pari a <span class="math-inline" data-math="6,00\text{ m}" data-index-in-node="153">6,00 m</span>, sottoposto a un carico di prova distribuito equivalente pari a <span class="math-inline" data-math="300\text{ kg/m}^2" data-index-in-node="231">300 kg/m²</span> (<span class="math-inline" data-math="3,00\text{ kN/m}^2" data-index-in-node="250">3,00 kN/m²</span>).</p>
<h3 data-path-to-node="8,8">2. Schema di Carico e Sistema di Contrasto</h3>
<p data-path-to-node="8,9">Onde evitare l&#8217;impiego di zavorre ingombranti e l&#8217;esecuzione di carotaggi/fori passanti sull&#8217;impalcato, si è optato per un&#8217;applicazione concentrata della forza equivalente tramite martinetto idraulico a spinta con capacità nominale fino a <span class="math-inline" data-math="25\text{ t}" data-index-in-node="239">25 t</span> (<span class="math-inline" data-math="250\text{ kN}" data-index-in-node="252">250 kN</span>).</p>
<ul data-path-to-node="8,10">
<li>
<p data-path-to-node="8,10,0,0">Ripartizione della spinta: In corrispondenza dell&#8217;estradosso/intradosso del punto di tiro, la spinta del pistone è stata ripartita mediante l&#8217;interposizione di un profilo metallico ad alta rigidità (trave in acciaio/putrella HEB) della lunghezza di <span class="math-inline" data-math="1,00\text{ m}" data-index-in-node="249">1,00 m</span>.</p>
</li>
<li>
<p data-path-to-node="8,10,1,0">Misura del carico: La forza applicata dal martinetto è stata monitorata in continuo mediante due trasduttori di pressione idraulica montati in serie al circuito di spinta della pompa idraulica.</p>
</li>
</ul>
<h3 data-path-to-node="8,12">3. Sistema di Misura delle Deformazioni e Acquisizione Dati</h3>
<p data-path-to-node="8,13">Per rilevare la freccia di inflessione e la linea elastica del solaio durante le fasi di carico e scarico, sono stati posizionati <span class="math-inline" data-math="5" data-index-in-node="130">5</span> trasduttori di spostamento ad alta precisione (LVDT / potenziometrici) disposti secondo la seguente configurazione:</p>
<ul data-path-to-node="8,14">
<li>
<p data-path-to-node="8,14,0,0"><span class="math-inline" data-math="2" data-index-in-node="0">2</span> trasduttori agli appoggi: per la misura ed il recupero dei cedimenti vincolari strutturali;</p>
</li>
<li>
<p data-path-to-node="8,14,1,0"><span class="math-inline" data-math="1" data-index-in-node="0">1</span> trasduttore in mezzeria: posizionato sulla verticale dell&#8217;asse di applicazione del carico;</p>
</li>
<li>
<p data-path-to-node="8,14,2,0"><span class="math-inline" data-math="2" data-index-in-node="0">2</span> trasduttori laterali: posizionati rispettivamente a <span class="math-inline" data-math="1,00\text{ m}" data-index-in-node="54">1,00 m</span> e <span class="math-inline" data-math="2,00\text{ m}" data-index-in-node="70">2,00 m</span> dalla mezzeria, per valutare il grado di collaborazione trasversale e la distribuzione del carico tra i travetti adiacenti.</p>
</li>
</ul>
<p data-path-to-node="8,15">I <span class="math-inline" data-math="5" data-index-in-node="2">5</span> sensori di spostamento e le celle di carico/pressione sono stati collegati a una centralina di acquisizione dati automatica a 16 canali (risoluzione <span class="math-inline" data-math="16\text{ bit}" data-index-in-node="153">16 bit</span>), interfacciata in tempo reale via USB <span class="math-inline" data-math="2.0" data-index-in-node="206">2.0</span> a un PC di gestione per il monitoraggio continuo delle curve carico-deformazione (σ<span class="math-inline" data-math="\sigma - \epsilon" data-index-in-node="292"> &#8211; ε</span>).</p>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/11/Insieme_di_prova.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Insieme_di_prova-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a spinta" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Insieme_di_prova-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/11/Insieme_di_prova-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/11/Grafico_carico_deformazioni.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Grafico_carico_deformazioni-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Grafico_carico_deformazioni-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/11/Grafico_carico_deformazioni-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/11/Contrasto_sul_pilastro.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Contrasto_sul_pilastro-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/11/Contrasto_sul_pilastro-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/11/Contrasto_sul_pilastro-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-a-spinta-padova/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">62</post-id>	</item>
		<item>
		<title>Prove di Carico Statico su Pavimentazione Industriale in C.A.</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-mestre-venezia/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-mestre-venezia/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Sun, 08 Feb 2015 15:55:20 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/16/motogp-makes-tyre-strategies-easier-to-follow-for-2017/</guid>

					<description><![CDATA[Nel mese di agosto 2014, in via dell’Azoto a Porto Marghera (VE), su incarico dello Studio “Arka Associati”, all’interno di un nuovo fabbricato ad uso artigianale, sono state eseguite due prove di carico su due porzioni di pavimentazione industriale in calcestruzzo armato.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="6,3">1. Inquadramento dell&#8217;Intervento</h3>
<p data-path-to-node="6,4">Nel mese di agosto 2014, su incarico dello Studio &#8220;Arka Associati&#8221;, sono state condotte due prove di carico statico su due distinte porzioni di pavimentazione industriale in calcestruzzo armato, all&#8217;interno di un nuovo fabbricato ad uso artigianale situato in via dell’Azoto a Porto Marghera (VE).</p>
<p data-path-to-node="6,5">Le operazioni di prova e monitoraggio sono state eseguite da operatori qualificati e certificati da RINA S.p.A. (organismo accreditato ACCREDIA) quali esperti di <span class="math-inline" data-math="III^\circ" data-index-in-node="162">III°</span> Livello per l&#8217;esecuzione di Prove Non Distruttive (PND) su strutture in c.a., c.a.p. e muratura.</p>
<h3 data-path-to-node="6,7">2. Allestimento del Sistema di Carico (Zavorra e Piastra)</h3>
<p data-path-to-node="6,8">Per sollecitare la pavimentazione fino ai livelli di carico previsti dal progetto, è stata allestita una zavorra composta da <span class="math-inline" data-math="10" data-index-in-node="125">10</span> blocchi prefabbricati in calcestruzzo, per un peso complessivo di circa <span class="math-inline" data-math="115\text{ t}" data-index-in-node="200">115 t</span>.</p>
<p data-path-to-node="6,9">I blocchi sono stati impilati al di sopra di una piastra di ripartizione in acciaio ad alta rigidità avente le seguenti caratteristiche:</p>
<ul data-path-to-node="6,10">
<li>
<p data-path-to-node="6,10,0,0">Dimensioni in pianta: <span class="math-inline" data-math="2,58 \times 3,03\text{ m}" data-index-in-node="22">2,58 x 3,03 m</span> (superficie d&#8217;impronta pari a <span class="math-inline" data-math="7,82\text{ m}^2" data-index-in-node="78">7,82 m²</span>);</p>
</li>
<li>
<p data-path-to-node="6,10,1,0">Spessore della piastra: <span class="math-inline" data-math="60\text{ mm}" data-index-in-node="24">60 mm</span>;</p>
</li>
<li>
<p data-path-to-node="6,10,2,0">Peso proprio della piastra: <span class="math-inline" data-math="2,4\text{ t}" data-index-in-node="28">2,4 t</span>.</p>
</li>
</ul>
<h3 data-path-to-node="6,12">3. Sistema di Rilievo dei Cedimenti (Livellazione Geometrica)</h3>
<p data-path-to-node="6,13">La misurazione periodica degli spostamenti verticali (cedimenti) della pavimentazione durante le fasi di carico e scarico è stata effettuata mediante <b data-path-to-node="6,13" data-index-in-node="150">livellazione geometrica di alta precisione</b>, impiegando un livello ottico-meccanico <b data-path-to-node="6,13" data-index-in-node="233">Assogeo mod. NA32</b> dotato di lamina a facce piano-parallele.</p>
<p data-path-to-node="6,14">Il rilievo altimetrico si basa sulla collimazione del reticolo del cannocchiale dell&#8217;autolivello su stadiette micrometriche graduate, previa accurata orizzontalizzazione dell&#8217;asse di mira.</p>
<ul data-path-to-node="6,15">
<li>
<p data-path-to-node="6,15,0,0"><b data-path-to-node="6,15,0,0" data-index-in-node="0">Capisaldi e punti di misura:</b> Sulla piastra d&#8217;impronta sono stati disposti <span class="math-inline" data-math="4" data-index-in-node="74">4</span> riferimenti di misura (uno su ciascun lato). Le variazioni di quota sono state determinate per confronto diretto con un caposaldo fisso di riferimento (<span class="math-inline" data-math="CS" data-index-in-node="228">CS</span>) posizionato esternamente all&#8217;area d&#8217;influenza del carico e ritenuto topograficamente stabile.</p>
</li>
<li>
<p data-path-to-node="6,15,1,0"><b data-path-to-node="6,15,1,0" data-index-in-node="0">Calcolo dei cedimenti:</b> Il cedimento differenziale Δ<span class="math-inline" data-math="\Delta l" data-index-in-node="50">l</span> registrato ai vari step di carico/scarico è calcolato mediante la relazione:</p>
</li>
</ul>
<div data-path-to-node="6,16">
<div class="math-block" style="text-align: center;" data-math="\Delta l = l - l'"><strong>ΔƖ = Ɩ &#8211; Ɩ’</strong></div>
</div>
<p data-path-to-node="6,17">dove:</p>
<ul data-path-to-node="6,18">
<li>
<p data-path-to-node="6,18,0,0"><span class="math-inline" data-math="l" data-index-in-node="0">l</span> è la lettura iniziale di zero a carico nullo;</p>
</li>
<li>
<p data-path-to-node="6,18,1,0"><span class="math-inline" data-math="l'" data-index-in-node="0">l&#8217;</span> è la lettura corrispondente allo specifico gradino di carico o di scarico.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/02/Area-della-prima-prova-di-carico.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Area-della-prima-prova-di-carico-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Area-della-prima-prova-di-carico-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/02/Area-della-prima-prova-di-carico-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/02/Carico-massimo.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Carico-massimo-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Carico-massimo-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/02/Carico-massimo-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2015/02/Zona-di-carico.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Zona-di-carico-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2015/02/Zona-di-carico-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2015/02/Zona-di-carico-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-mestre-venezia/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">65</post-id>	</item>
		<item>
		<title>Verifica Strutturale in Situ e Collaudo della Rete Anticaduta dell&#8217;Elisuperficie</title>
		<link>https://www.structuralsurveys.it/lavori/verifica-strutturale-di-una-mensola/</link>
					<comments>https://www.structuralsurveys.it/lavori/verifica-strutturale-di-una-mensola/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Fri, 13 Dec 2013 15:57:41 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/01/19/ducati-has-all-the-cards-to-win-2017-motogp-title-says-ceo/</guid>

					<description><![CDATA[La prova di carico ha lo scopo di accertare la corrispondenza sperimentale con quella teorica e si esegue su strutture di nuova costruzione. I materiali degli elementi sottoposti a prove di carico devono aver raggiunto le resistenze previste per il loro funzionamento finale in esercizio.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="7,3">1. Inquadramento Generale e Scopo delle Prove</h3>
<p data-path-to-node="7,5">Nel mese di dicembre 2013, presso il parcheggio <b data-path-to-node="7,5" data-index-in-node="48">&#8220;Autosilos Busonera&#8221;</b> situato in via Gattamelata a Padova, è stata eseguita una campagna di prove di carico in situ finalizzata a:</p>
<ol start="1" data-path-to-node="7,6">
<li>
<p data-path-to-node="7,6,0,0">Verificare la capacità portante delle travi d&#8217;acciaio modificate a supporto della rete perimetrale dell&#8217;elidromo;</p>
</li>
<li>
<p data-path-to-node="7,6,1,0">Verificare la resistenza e la deformabilità della rete di protezione anticaduta a servizio dell&#8217;elisuperficie posta sulla copertura del fabbricato.</p>
</li>
</ol>
<p data-path-to-node="7,7">Le strutture d&#8217;inquadramento della rete di protezione sono costituite da profili d&#8217;acciaio <b data-path-to-node="7,7" data-index-in-node="91">HEA 120 e HEA 140</b> posati in opera durante la costruzione dell&#8217;edificio. Su richiesta della Committenza, si è proceduto alla verifica sperimentale di una trave prolungata per un carico di progetto pari a <b data-path-to-node="7,7" data-index-in-node="294"><span class="math-inline" data-math="6\text{ kN}" data-index-in-node="294">6 kN</span></b> e della rete di protezione per un carico concentrato di <b data-path-to-node="7,7" data-index-in-node="362"><span class="math-inline" data-math="1{,}5\text{ kN}" data-index-in-node="362">1,5 kN</span> (<span class="math-inline" data-math="\approx 150\text{ kg}" data-index-in-node="379">150 kg</span>)</b>.</p>
<h3 data-path-to-node="7,9">2. Setup Sperimentale e Modalità di Sollecitazione</h3>
<h4 data-path-to-node="7,10">A. Prova di Categoria 1: Sollecitazione della Trave d&#8217;Acciaio</h4>
<p data-path-to-node="7,11">Per la misurazione delle deformazioni e degli abbassamenti della trave HEA prolungata, sono stati posizionati <b data-path-to-node="7,11" data-index-in-node="110">n. 3 punti di rilievo deformometrici</b>:</p>
<ul data-path-to-node="7,12">
<li>
<p data-path-to-node="7,12,0,0"><b data-path-to-node="7,12,0,0" data-index-in-node="0">N. 2 sensori</b> sulla trave verificata, in corrispondenza del profilo aggiunto in estensione;</p>
</li>
<li>
<p data-path-to-node="7,12,1,0"><b data-path-to-node="7,12,1,0" data-index-in-node="0">N. 1 sensore caposaldo (Riferimento zero)</b> posizionato esternamente alla zona d&#8217;influenza della prova, per l&#8217;eliminazione dei moti rigidi della struttura.</p>
</li>
</ul>
<p data-path-to-node="7,13">La trave è stata sollecitata in trazione/flessione mediante un sistema oleodinamico costituito da:</p>
<ul data-path-to-node="7,14">
<li>
<p data-path-to-node="7,14,0,0">Martinetto idraulico traente Enerpac con area effettiva del pistone <span class="math-inline" data-math="A = 15\text{ cm}^2" data-index-in-node="68">A = 15 cm²</span>;</p>
</li>
<li>
<p data-path-to-node="7,14,1,0">Fune metallica ad alta resistenza collegata al martinetto;</p>
</li>
<li>
<p data-path-to-node="7,14,2,0">Piastra di contrasto ancorata alla pavimentazione stradale sottostante mediante tasselli meccanici ad espansione.</p>
</li>
</ul>
<h4 data-path-to-node="7,15">B. Prova di Categoria 2: Verifica Locale della Rete Anticaduta</h4>
<p data-path-to-node="7,16">In corso d&#8217;opera, la Committenza ha richiesto di estendere la verifica alla valutazione del comportamento deformativo della rete anticaduta in due punti di potenziale impatto.</p>
<p data-path-to-node="7,17">Per distribuire il carico sul reticolo in corda/maglia metallica, è stata posizionata una traversina in legno di ripartizione (lunghezza pari a circa <span class="math-inline" data-math="1{,}0\text{ m}" data-index-in-node="150">1,0 m</span>) collegata alla fune di trazione. Il contrasto oleodinamico è stato fornito ancorando il martinetto al gancio di traino anteriore di un automezzo di servizio posizionato a terra.</p>
<h3 data-path-to-node="7,19">3. Esito delle Prove di Carico e Conclusioni</h3>
<ul data-path-to-node="7,20">
<li>
<p data-path-to-node="7,20,0,0"><b data-path-to-node="7,20,0,0" data-index-in-node="0">Trave in acciaio HEA:</b> Sotto il carico massimo di prova (<span class="math-inline" data-math="6\text{ kN}" data-index-in-node="56">6 kN</span>), la trave ha mostrato un comportamento perfettamente elastico, con deformazioni contenute nei limiti normativi di freccia ammissibile e completo rientro elastico al momento dello scarico;</p>
</li>
<li>
<p data-path-to-node="7,20,1,0"><b data-path-to-node="7,20,1,0" data-index-in-node="0">Rete anticaduta:</b> Sotto l&#8217;azione del carico nominale di <span class="math-inline" data-math="1{,}5\text{ kN}" data-index-in-node="55">1,5 kN</span>, la rete e le relative unioni (sistemi di aggancio tra rete, cavi perimetrali e tubolari di supporto) non hanno evidenziato cedimenti, snervamenti o plasticizzazioni dei giunti.</p>
</li>
</ul>
<p data-path-to-node="7,21">Le indagini sperimentali hanno pertanto dato esito positivo, confermando l&#8217;idoneità statica e la sicurezza d&#8217;esercizio dei sistemi anticaduta dell&#8217;elisuperficie.</p>
<h3 data-path-to-node="7,23">4. Riferimenti Normativi</h3>
<ul data-path-to-node="7,24">
<li>
<p data-path-to-node="7,24,0,0"><b data-path-to-node="7,24,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="7,24,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico e prove di carico sulle strutture</i>;</p>
</li>
<li>
<p data-path-to-node="7,24,1,0"><b data-path-to-node="7,24,1,0" data-index-in-node="0">UNI EN 1263-1 / 2:</b> <i data-path-to-node="7,24,1,0" data-index-in-node="19">Reti di sicurezza &#8211; Requisiti di sicurezza e metodi di prova</i>;</p>
</li>
<li>
<p data-path-to-node="7,24,2,0"><b data-path-to-node="7,24,2,0" data-index-in-node="0">UNI EN 795:</b> <i data-path-to-node="7,24,2,0" data-index-in-node="12">Dispositivi anticaduta e sistemi di ancoraggio per coperture</i>.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Applicazione-del-carico.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Applicazione-del-carico-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Applicazione-del-carico-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Applicazione-del-carico-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Eliporto-Busonera.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Eliporto-Busonera-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Eliporto-Busonera-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Eliporto-Busonera-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Punti-di-rilievo.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Punti-di-rilievo-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Punti-di-rilievo-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Punti-di-rilievo-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Rilievo-dati.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Rilievo-dati-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Rilievo-dati-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Rilievo-dati-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/verifica-strutturale-di-una-mensola/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">93</post-id>	</item>
		<item>
		<title>Prova di Carico Statico di Collaudo sulla Copertura Metallica della Chiesa del S.S. Redentore</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-statico-su-una-copertura-piana/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-statico-su-una-copertura-piana/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Wed, 11 Dec 2013 15:56:45 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/01/30/dota-pit-season-5-finals-preview-secret-vp-have-something-to-prove/</guid>

					<description><![CDATA[In data 04 dicembre 2013, in via Costa Calcinara 101, a Monselice provincia di Padova, su incarico della Parrocchia Del S.S. Redentore, è stato eseguito una prova di carico statico sulla copertura della chiesa. La zona dove effettuare la prova è stato scelto in collaborazione con il Collaudatore statico.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="6,3">1. Inquadramento Generale e Scopo delle Prove</h3>
<p data-path-to-node="6,4">In data 4 dicembre 2013, presso il complesso parrocchiale del S.S. Redentore in via Costa Calcinara 101 a Monselice (PD), su incarico della Committenza Parrocchiale e sotto la direzione del Collaudatore Statico, è stata eseguita una <b data-path-to-node="6,4" data-index-in-node="233">prova di carico statico di collaudo</b> sulla struttura di copertura dell&#8217;edificio di culto.</p>
<p data-path-to-node="6,5">Le operazioni diagnostiche sono state condotte da tecnici sperimentatori qualificati e certificati da RINA S.p.A. (Organismo Accreditato ACCREDIA) come Esperti di <span class="math-inline" data-math="III^\circ" data-index-in-node="163">III°</span> Livello per l&#8217;esecuzione di controlli non distruttivi e prove di carico su strutture in c.a., c.a.p. e carpenteria metallica (UNI EN ISO 9712).</p>
<h3 data-path-to-node="6,7">2. Schema Strutturale della Copertura</h3>
<p data-path-to-node="6,8">La copertura della chiesa presenta una struttura portante in carpenteria metallica a quattro falde a debole pendenza, sostenuta da n. 4 pilastri principali in calcestruzzo armato.</p>
<p data-path-to-node="6,9">Il sistema principale di travature è composto da capriate in acciaio disposte a raggiera (&#8220;fascio&#8221;) convergenti in un nodo centrale comune di colmo, dal quale aggettano due porzioni in sbalzo perimetrali.</p>
<h3 data-path-to-node="6,11">3. Setup Sperimentale, Sistemi di Carico e Catena di Misura</h3>
<h4 data-path-to-node="6,12">A. Modalità di Applicazione del Carico (Zavorre Idriche)</h4>
<p data-path-to-node="6,13">L&#8217;area di carico e la disposizione dei punti di misura sono state individuate in coordinamento con il Collaudatore Statico. Il carico ripartito è stato applicato gradualmente posizionando al di sopra di una delle capriate diagonali del quadrante centrale:</p>
<ul data-path-to-node="6,14">
<li>
<p data-path-to-node="6,14,0,0"><b data-path-to-node="6,14,0,0" data-index-in-node="0">N. 1 serbatoio flessibile idrico</b> con impronta superficiale di <span class="math-inline" data-math="16\text{ m}^2" data-index-in-node="62">16 m²</span>;</p>
</li>
<li>
<p data-path-to-node="6,14,1,0"><b data-path-to-node="6,14,1,0" data-index-in-node="0">N. 2 vasche/piscine estensibili</b> per una superficie aggiuntiva di <span class="math-inline" data-math="16\text{ m}^2" data-index-in-node="65">16 m²</span>.</p>
</li>
</ul>
<p data-path-to-node="6,15">Superficie complessiva d&#8217;impronta del carico idrico: <b data-path-to-node="6,15" data-index-in-node="53"><span class="math-inline" data-math="32\text{ m}^2" data-index-in-node="53">32 m²</span></b>.</p>
<h4 data-path-to-node="6,16">B. Sistema Topometrico di Rilievo della Freccia</h4>
<p data-path-to-node="6,17">Il monitoraggio delle deformazioni verticali (frecce d&#8217;abbassamento) è stato eseguito mediante <b data-path-to-node="6,17" data-index-in-node="95">livellazione geometrica di alta precisione</b>:</p>
<ul data-path-to-node="6,18">
<li>
<p data-path-to-node="6,18,0,0"><b data-path-to-node="6,18,0,0" data-index-in-node="0">Strumentazione:</b> Autolivello ottico-meccanico di precisione (Assogeo / Leica NA32);</p>
</li>
<li>
<p data-path-to-node="6,18,1,0"><b data-path-to-node="6,18,1,0" data-index-in-node="0">Ottica aggiuntiva:</b> Micrometro a lamina pianparallela applicato all&#8217;obiettivo, con risoluzione di lettura diretta pari a <span class="math-inline" data-math="0{,}1\text{ mm}" data-index-in-node="120">0,1 mm</span> e stima visiva fino a <span class="math-inline" data-math="0{,}01\text{ mm}" data-index-in-node="158">0,01 mm</span>;</p>
</li>
<li>
<p data-path-to-node="6,18,2,0"><b data-path-to-node="6,18,2,0" data-index-in-node="0">Punti di misura (Mire ottiche):</b></p>
<ul data-path-to-node="6,18,2,1">
<li>
<p data-path-to-node="6,18,2,1,0,0"><b data-path-to-node="6,18,2,1,0,0" data-index-in-node="0">N. 4 mira-bersaglio</b> posizionate agli angoli del quadrante concentrico al nodo centrale;</p>
</li>
<li>
<p data-path-to-node="6,18,2,1,1,0"><b data-path-to-node="6,18,2,1,1,0" data-index-in-node="0">N. 2 mira-bersaglio</b> posizionate sulle estremità dei tratti in sbalzo;</p>
</li>
<li>
<p data-path-to-node="6,18,2,1,2,0"><b data-path-to-node="6,18,2,1,2,0" data-index-in-node="0">Caposaldo esterno di Riferimento (Caposaldo di Zero):</b> Posizionato su elemento strutturale indeformabile fuori dalla zona d&#8217;influenza della prova per la depurazione dei moti rigidi.</p>
</li>
</ul>
</li>
</ul>
<h3 data-path-to-node="6,20">4. Esito delle Misurazioni e Risultati</h3>
<p data-path-to-node="6,21">Durante la fase di massimo carico nominale di prova, la risposta deformativa della carpenteria metallica si è mantenuta entro i valori teorici prestabiliti dal progetto:</p>
<ul data-path-to-node="6,22">
<li>
<p data-path-to-node="6,22,0,0"><b data-path-to-node="6,22,0,0" data-index-in-node="0">Freccia massima flessionale in mezzeria:</b> Rilevata in corrispondenza del nodo centrale con un valore massimo pari a <b data-path-to-node="6,22,0,0" data-index-in-node="115"><span class="math-inline" data-math="\delta_{max} = 7{,}6\text{ mm}" data-index-in-node="115">Δmax = 7,6 mm</span></b>;</p>
</li>
<li>
<p data-path-to-node="6,22,1,0"><b data-path-to-node="6,22,1,0" data-index-in-node="0">Rientro elastico allo scarico:</b> A seguito dello svuotamento dei serbatoi idrici, la struttura ha mostrato un completo rientro elastico delle deformazioni (assenza di frecce residue permanenti significative).</p>
</li>
</ul>
<p data-path-to-node="6,23">La prova di carico ha pertanto dato esito positivo, confermando la perfetta efficienza statica della copertura.</p>
<h3 data-path-to-node="6,25">5. Normativa di Riferimento</h3>
<ul data-path-to-node="6,26">
<li>
<p data-path-to-node="6,26,0,0"><b data-path-to-node="6,26,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="6,26,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico e prove di carico su strutture metalliche</i>;</p>
</li>
<li>
<p data-path-to-node="6,26,1,0"><b data-path-to-node="6,26,1,0" data-index-in-node="0">Circolare Applicativa n. 7/2019:</b> <i data-path-to-node="6,26,1,0" data-index-in-node="33">Istruzioni per l&#8217;esecuzione del collaudo statico mediante carichi ripartiti idrici</i>;</p>
</li>
<li>
<p data-path-to-node="6,26,2,0"><b data-path-to-node="6,26,2,0" data-index-in-node="0">UNI ISO 17123-2:</b> <i data-path-to-node="6,26,2,0" data-index-in-node="17">Ottica e strumenti ottici &#8211; Procedure di prova sul campo per strumenti geodetici &#8211; Livelli</i>.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Carico-massimo.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Carico-massimo-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Carico-massimo-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Carico-massimo-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Nodo-centrale-della-struttura.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Nodo-centrale-della-struttura-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Nodo-centrale-della-struttura-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Nodo-centrale-della-struttura-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Sistema-rilievo-dati.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Sistema-rilievo-dati-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Sistema-rilievo-dati-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Sistema-rilievo-dati-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/12/Vista-dal-satellite.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Vista-dal-satellite-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/12/Vista-dal-satellite-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/12/Vista-dal-satellite-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-statico-su-una-copertura-piana/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">82</post-id>	</item>
		<item>
		<title>Prova di Carico Statico di Collaudo su Terrazzo a Sbalzo in Calcestruzzo Armato</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-statica-su-un-terrazzo-a-sbalzo/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-statica-su-un-terrazzo-a-sbalzo/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Fri, 13 Sep 2013 14:56:30 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/02/the-heart-of-nintendos-new-console-isnt-the-switch/</guid>

					<description><![CDATA[L'oggetto della prova di carico era la verifica statica di un terrazzo a sbalzo (balcone) in calcestruzzo armato, in un nuovo costruendo in zona Fossolo a Bologna.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="6,3">1. Inquadramento dell&#8217;Opera e Scopo della Prova</h3>
<p data-path-to-node="6,4">L&#8217;oggetto dell&#8217;indagine sperimentale riguarda la verifica statica e deformativa di un terrazzo a sbalzo (balcone) in calcestruzzo armato, facente parte di un nuovo edificio a destinazione residenziale in fase di costruzione nel quartiere <i data-path-to-node="6,4" data-index-in-node="238">Fossolo</i> a Bologna.</p>
<p data-path-to-node="6,5"><b data-path-to-node="6,5" data-index-in-node="0">Caratteristiche geometriche del manufatto:</b></p>
<ul data-path-to-node="6,6">
<li>
<p data-path-to-node="6,6,0,0"><b data-path-to-node="6,6,0,0" data-index-in-node="0">Ubicazione:</b> Piano <span class="math-inline" data-math="4^\circ" data-index-in-node="18">4</span>;</p>
</li>
<li>
<p data-path-to-node="6,6,1,0"><b data-path-to-node="6,6,1,0" data-index-in-node="0">Luce netta di sbalzo (<span class="math-inline" data-math="L" data-index-in-node="22">L</span>):</b> <span class="math-inline" data-math="1{,}90\text{ m}" data-index-in-node="26">1,90 m</span>;</p>
</li>
<li>
<p data-path-to-node="6,6,2,0"><b data-path-to-node="6,6,2,0" data-index-in-node="0">Larghezza frontale (<span class="math-inline" data-math="B" data-index-in-node="20">B</span>):</b> <span class="math-inline" data-math="6{,}00\text{ m}" data-index-in-node="24">6,00 m</span>.</p>
</li>
</ul>
<p data-path-to-node="6,7">Su indicazione congiunta del Progettista Strutturale e del Collaudatore Statico, è stata programmata la verifica sperimentale per un carico nominale uniformemente distribuito pari a <span class="math-inline" data-math="q = 600\text{ kg/m}^2" data-index-in-node="182">q = 600 kg/m²</span> (<span class="math-inline" data-math="6{,}0\text{ kN/m}^2" data-index-in-node="205">6,0 kN/m²</span>). La prova è stata eseguita a oltre 28 giorni dal completamento del getto della soletta, prima dell&#8217;esecuzione dei massetti, delle impermeabilizzazioni e delle finiture superficiali.</p>
<h3 data-path-to-node="6,9">2. Modello Teorico ed Equivalenza dello Schema di Carico</h3>
<p data-path-to-node="6,10">Per evitare il posizionamento di gravose zavorre distribuite (blocchi di calcestruzzo o sacchi di sabbia) al quarto piano, la prova è stata condotta applicando una forza concentrata equivalente mediante un sistema di tiro oleodinamico.</p>
<p data-path-to-node="6,11">Modellando la porzione unitaria di sbalzo come una trave-mensola incastrata alla base, l&#8217;equivalenza dello stato di sollecitazione al filo dell&#8217;incastro si basa sull&#8217;uguaglianza del momento flettente massimo <span class="math-inline" data-math="M_{max}" data-index-in-node="208">Mmax</span>:</p>
<div data-path-to-node="6,12">
<div class="math-block" data-math="M_{incastro} = \frac{q \cdot L^2}{2} = P \cdot b"><img loading="lazy" decoding="async" class="aligncenter wp-image-4510" src="https://www.structuralsurveys.it/wp-content/uploads/2013/09/momento_incastro-removebg-preview.png" alt="" width="250" height="64" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/09/momento_incastro-removebg-preview.png 398w, https://www.structuralsurveys.it/wp-content/uploads/2013/09/momento_incastro-removebg-preview-300x77.png 300w" sizes="(max-width: 250px) 100vw, 250px" /></div>
</div>
<p data-path-to-node="6,13">Dove:</p>
<ul data-path-to-node="6,14">
<li>
<p data-path-to-node="6,14,0,0"><b data-path-to-node="6,14,0,0" data-index-in-node="0"><span class="math-inline" data-math="q" data-index-in-node="0">q</span></b> = Carico distribuito di progetto (<span class="math-inline" data-math="6{,}0\text{ kN/m}^2" data-index-in-node="36">6,0 kN/m²</span>);</p>
</li>
<li>
<p data-path-to-node="6,14,1,0"><b data-path-to-node="6,14,1,0" data-index-in-node="0"><span class="math-inline" data-math="L" data-index-in-node="0">L</span></b> = Luce dello sbalzo (<span class="math-inline" data-math="1{,}90\text{ m}" data-index-in-node="23">1,90 m</span>);</p>
</li>
<li>
<p data-path-to-node="6,14,2,0"><b data-path-to-node="6,14,2,0" data-index-in-node="0"><span class="math-inline" data-math="P" data-index-in-node="0">P</span></b> = Forza concentrata equivalente applicata dal martinetto (<span class="math-inline" data-math="\text{kN}" data-index-in-node="60">kN</span>);</p>
</li>
<li>
<p data-path-to-node="6,14,3,0"><b data-path-to-node="6,14,3,0" data-index-in-node="0"><span class="math-inline" data-math="b" data-index-in-node="0">b</span></b> = Braccio della forza dal filo dell&#8217;incastro (<span class="math-inline" data-math="\text{m}" data-index-in-node="48">m</span>).</p>
</li>
</ul>
<p data-path-to-node="6,15">Sulla base di tale uguaglianza, la sollecitazione è stata applicata in due cicli incrementali di carico:</p>
<ul data-path-to-node="6,16">
<li>
<p data-path-to-node="6,16,0,0"><b data-path-to-node="6,16,0,0" data-index-in-node="0"><span class="math-inline" data-math="I^\circ" data-index-in-node="0">I° </span>Ciclo di carico:</b> Forza applicata pari a <b data-path-to-node="6,16,0,0" data-index-in-node="48"><span class="math-inline" data-math="0{,}9\text{ t}" data-index-in-node="48">0,9 t</span> (<span class="math-inline" data-math="\approx 9\text{ kN}" data-index-in-node="64">9 kN</span>)</b>;</p>
</li>
<li>
<p data-path-to-node="6,16,1,0"><b data-path-to-node="6,16,1,0" data-index-in-node="0"><span class="math-inline" data-math="II^\circ" data-index-in-node="0">II°</span> Ciclo di carico (Carico Massimo di Prova):</b> Forza applicata pari a <b data-path-to-node="6,16,1,0" data-index-in-node="75"><span class="math-inline" data-math="2{,}0\text{ t}" data-index-in-node="75">2,0 t</span> (<span class="math-inline" data-math="\approx 20\text{ kN}" data-index-in-node="91">20 kN</span>)</b>.</p>
</li>
</ul>
<h3 data-path-to-node="6,18">3. Setup Sperimentale e Catena di Misura</h3>
<h4 data-path-to-node="6,19">A. Sistema di Sollecitazione Oleodinamico</h4>
<p data-path-to-node="6,20">La forza di tiro è stata generata mediante un martinetto idraulico traente Enerpac BRC106 con capacità massima di <span class="math-inline" data-math="106\text{ kN}" data-index-in-node="114">106 kN</span> ed area effettiva di trazione <span class="math-inline" data-math="A = 15\text{ cm}^2" data-index-in-node="158">A = 15 cm²</span>, collegato a una centralina idraulica di alta precisione e ancorato a un contrasto strutturale inferiore.</p>
<h4 data-path-to-node="6,21">B. Disposizione dei Sensori di Spostamento</h4>
<p data-path-to-node="6,22">Il rilievo delle deformazioni verticali (frecce) e della risposta cinetica è stato affidato a n. 5 trasduttori di spostamento (LVDT / potenziometrici) disposti secondo lo schema seguente:</p>
<ol start="1" data-path-to-node="6,23">
<li>
<p data-path-to-node="6,23,0,0"><b data-path-to-node="6,23,0,0" data-index-in-node="0">Sensore 1 (All&#8217;appoggio/incastro):</b> Monitoraggio degli eventuali assestamenti o rotazioni della sezione di incastro;</p>
</li>
<li>
<p data-path-to-node="6,23,1,0"><b data-path-to-node="6,23,1,0" data-index-in-node="0">Sensore 2 (In corrispondenza del punto di tiro):</b> Misura della freccia massima nel punto di applicazione del carico;</p>
</li>
<li>
<p data-path-to-node="6,23,2,0"><b data-path-to-node="6,23,2,0" data-index-in-node="0">Sensori 3 e 4 (Collaborazione trasversale):</b> Posizionati lungo l&#8217;orlo libero rispettivamente a <span class="math-inline" data-math="1{,}1\text{ m}" data-index-in-node="94">1,1 m</span> e <span class="math-inline" data-math="2{,}2\text{ m}" data-index-in-node="111">2,2 m</span> dal punto di tiro per valutare l&#8217;effetto di ripartizione bidimensionale della soletta;</p>
</li>
<li>
<p data-path-to-node="6,23,3,0"><b data-path-to-node="6,23,3,0" data-index-in-node="0">Sensore 5 (Solaio di vincolo interno):</b> Monitoraggio della deformazione o sollevamento del solaio contiguo all&#8217;interno dell&#8217;appartamento.</p>
</li>
</ol>
<h3 data-path-to-node="6,25">4. Risultati Sperimentali e Giudizio di Collaudo</h3>
<p data-path-to-node="6,26">Il collaudo statico dell&#8217;elemento si basa sul confronto diretto tra la freccia sperimentale misurata (Δ<span class="math-inline" data-math="\delta_{sper}" data-index-in-node="102">sper</span>) sotto il massimo carico di prova e la freccia teorica di calcolo (Δ<span class="math-inline" data-math="\delta_{teor}" data-index-in-node="183">teor</span>) ricavata dai modelli analitici di rigidezza flessionale dell&#8217;elemento in c.a. fessurato/reagente.</p>
<ul data-path-to-node="6,27">
<li>
<p data-path-to-node="6,27,0,0"><b data-path-to-node="6,27,0,0" data-index-in-node="0">Comportamento Deformativo:</b> La freccia massima registrata in corrispondenza del punto di tiro è risultata inferiore rispetto al valore massimo ammissibile teorico;</p>
</li>
<li>
<p data-path-to-node="6,27,1,0"><b data-path-to-node="6,27,1,0" data-index-in-node="0">Rientro Elastico:</b> A seguito dello scarico completo, si è registrato un rapido e quasi totale rientro elastico delle deformazioni, confermando l&#8217;assenza di plasticizzazioni nell&#8217;armatura o fessurazioni anomale nel calcestruzzo;</p>
</li>
<li>
<p data-path-to-node="6,27,2,0"><b data-path-to-node="6,27,2,0" data-index-in-node="0">Collaborazione Spaziale:</b> I sensori laterali hanno evidenziato un&#8217;ottima risposta d&#8217;insieme della piastra in c.a.</p>
</li>
</ul>
<p data-path-to-node="6,28">La prova di carico ha dato esito positivo, confermando la piena idoneità statica del terrazzo a sbalzo.</p>
<h3 data-path-to-node="6,30">5. Normativa di Riferimento</h3>
<ul data-path-to-node="6,31">
<li>
<p data-path-to-node="6,31,0,0"><b data-path-to-node="6,31,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="6,31,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico e prove di carico sulle strutture in c.a.</i>;</p>
</li>
<li>
<p data-path-to-node="6,31,1,0"><b data-path-to-node="6,31,1,0" data-index-in-node="0">Circolare Applicativa n. 7/2019:</b> <i data-path-to-node="6,31,1,0" data-index-in-node="33">Istruzioni per l&#8217;esecuzione del collaudo statico e criteri di accettazione delle deformazioni</i>;</p>
</li>
<li>
<p data-path-to-node="6,31,2,0"><b data-path-to-node="6,31,2,0" data-index-in-node="0">UNI 10838:</b> <i data-path-to-node="6,31,2,0" data-index-in-node="11">Edilizia &#8211; Terminologia e classificazione dei controlli sulle strutture destinate alle costruzioni</i>.</p>
</li>
</ul>
<div dir="ltr" data-font-name="Helvetica" data-canvas-width="103.85760309519767">

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/09/Contrasto-inferiore.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Contrasto-inferiore-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Contrasto-inferiore-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/09/Contrasto-inferiore-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Cedimenti.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Cedimenti-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Cedimenti-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Cedimenti-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Tempo.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Tempo-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Tempo-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/09/Grafico-Carico-Tempo-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/09/Sitema-idraulico-di-carico.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Sitema-idraulico-di-carico-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="prova di carico a tiro" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/09/Sitema-idraulico-di-carico-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/09/Sitema-idraulico-di-carico-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-statica-su-un-terrazzo-a-sbalzo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">79</post-id>	</item>
		<item>
		<title>Prova di Carico Statico di Collaudo su Soppalco Metallico</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-su-un-soppalco/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-su-un-soppalco/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Thu, 11 Jul 2013 14:56:36 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/01/12-things-you-didnt-see-during-the-2017-golden-globes/</guid>

					<description><![CDATA[In pieno centro storico della città di Bologna, in un edificio che per molti anni conduceva ad un cinema, su incarico di una Società Cooperativa di Bologna, è stato eseguito una prova di carico statica su un soppalco con struttura di sostegno principali UPN 200 e secondarie HEB 180.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="7,3">1. Inquadramento dell&#8217;Edificio e Scopo delle Prove</h3>
<p data-path-to-node="7,4">In pieno centro storico a Bologna, all&#8217;interno di un immobile d&#8217;epoca storicamente destinato ad atrio d&#8217;accesso di una sala cinematografica, è stata eseguita una prova di carico statico di collaudo su un soppalco di nuova realizzazione. L&#8217;intervento è stato commissionato da una Società Cooperativa di Bologna.</p>
<p data-path-to-node="7,5">Le operazioni diagnostiche sono state condotte da tecnici sperimentatori qualificati e certificati da RINA S.p.A. (Organismo Accreditato ACCREDIA) come Esperti di <span class="math-inline" data-math="III^\circ" data-index-in-node="163">III°</span> Livello addetti alle prove e controlli non distruttivi su strutture in c.a., c.a.p., muratura e carpenteria metallica (UNI EN ISO 9712).</p>
<p data-path-to-node="7,6"><b data-path-to-node="7,6" data-index-in-node="0">Inquadramento della carpenteria metallica:</b></p>
<ul data-path-to-node="7,7">
<li>
<p data-path-to-node="7,7,0,0"><b data-path-to-node="7,7,0,0" data-index-in-node="0">Orditura principale:</b> Travi reticolari/profilati a canale <b data-path-to-node="7,7,0,0" data-index-in-node="57">UPN 200</b>;</p>
</li>
<li>
<p data-path-to-node="7,7,1,0"><b data-path-to-node="7,7,1,0" data-index-in-node="0">Orditura secondaria:</b> Profilati ad ali larghe <b data-path-to-node="7,7,1,0" data-index-in-node="45">HEB 180</b>.</p>
</li>
</ul>
<p data-path-to-node="7,8">La verifica sperimentale è stata richiesta per un carico accidentale distribuito totale pari a <span class="math-inline" data-math="q = 400\text{ kg/m}^2" data-index-in-node="95">q = 400 kg/m² </span>(<span class="math-inline" data-math="4{,}0\text{ kN/m}^2" data-index-in-node="118">4,0 kN/m²</span>).</p>
<h3 data-path-to-node="7,10">2. Vincoli Operativi e Setup di Sollecitazione a Spinta</h3>
<p data-path-to-node="7,11">La presenza dell&#8217;impianto di riscaldamento radiante a pavimento, già posato ed installato dall&#8217;impresa esecutrice al di sotto della pavimentazione, ha reso impossibile la realizzazione di fori d&#8217;ancoraggio passanti per l&#8217;impiego dei classici sistemi di tiro idraulico a trazione.</p>
<p data-path-to-node="7,12">Per ovviare a tale vincolo, si è adottato un sistema di sollecitazione idraulico a spinta, posizionando il martinetto idraulico direttamente sul solaio di soppalco e contrastando la spinta contro gli elementi strutturali superiori sovrastanti (o contrasto a portale).</p>
<p data-path-to-node="7,13">Modellando la campata come una trave appoggiata e considerando la collaborazione trasversale dell&#8217;impalcato, il carico distribuito nominale è stato convertito in una forza concentrata equivalente in mezzeria, applicata in due cicli incrementali:</p>
<ul data-path-to-node="7,14">
<li>
<p data-path-to-node="7,14,0,0"><b data-path-to-node="7,14,0,0" data-index-in-node="0"><span class="math-inline" data-math="I^\circ" data-index-in-node="0">I°</span> Ciclo di carico:</b> Forza applicata pari a <span class="math-inline" data-math="1{,}5\text{ t}" data-index-in-node="48">1,5 t</span> (<span class="math-inline" data-math="\approx 15\text{ kN}" data-index-in-node="64">15 kN</span>);</p>
</li>
<li>
<p data-path-to-node="7,14,1,0"><b data-path-to-node="7,14,1,0" data-index-in-node="0"><span class="math-inline" data-math="II^\circ" data-index-in-node="0">II°</span> Ciclo di carico (Carico Massimo di Prova):</b> Forza applicata pari a <span class="math-inline" data-math="3{,}5\text{ t}" data-index-in-node="75">3,5 t</span> (<span class="math-inline" data-math="\approx 35\text{ kN}" data-index-in-node="91">35</span>).</p>
</li>
</ul>
<h3 data-path-to-node="7,16">3. Catena di Misura e Disposizione dei Sensori</h3>
<p data-path-to-node="7,17">Il rilievo delle frecce e della risposta cinetica è stato affidato a n. 5 trasduttori di spostamento (LVDT / potenziometrici) disposti secondo il seguente schema:</p>
<ol start="1" data-path-to-node="7,18">
<li>
<p data-path-to-node="7,18,0,0"><b data-path-to-node="7,18,0,0" data-index-in-node="0">Sensori 1 e 2 (In corrispondenza degli appoggi):</b> Rilievo dei cedimenti d&#8217;estremità e calibrazione per l&#8217;eliminazione dei moti rigidi della struttura;</p>
</li>
<li>
<p data-path-to-node="7,18,1,0"><b data-path-to-node="7,18,1,0" data-index-in-node="0">Sensore 3 (In mezzeria della campata):</b> Posizionato in corrispondenza dell&#8217;asse del punto di spinta per la misura della freccia massima;</p>
</li>
<li>
<p data-path-to-node="7,18,2,0"><b data-path-to-node="7,18,2,0" data-index-in-node="0">Sensori 4 e 5 (Collaborazione trasversale):</b> Posizionati lateralmente sulla struttura secondaria per valutare la ripartizione spaziale del carico.</p>
</li>
</ol>
<h3 data-path-to-node="7,20">4. Risultati e Giudizio di Collaudo</h3>
<p data-path-to-node="7,21">L&#8217;analisi dei diagrammi carico-deformazione ha evidenziato la piena efficienza statica della carpenteria metallica:</p>
<ul data-path-to-node="7,22">
<li>
<p data-path-to-node="7,22,0,0"><b data-path-to-node="7,22,0,0" data-index-in-node="0">Comportamento Deformativo:</b> Le frecce elastiche registrate in mezzeria sotto il massimo carico di prova (<span class="math-inline" data-math="3{,}5\text{ t}" data-index-in-node="104">3,5 t</span>) si sono mantenute ampiamente inferiori ai limiti teorici previsti dalle NTC;</p>
</li>
<li>
<p data-path-to-node="7,22,1,0"><b data-path-to-node="7,22,1,0" data-index-in-node="0">Rientro Elastico:</b> Allo scarico completo della pressione idraulica, la struttura ha mostrato un comportamento perfettamente elastico, con deformazioni residue permanenti minime e prossime al decimo di millimetro (δ<span class="math-inline" data-math="\delta_{res} \approx 0{,}1\text{ mm}" data-index-in-node="212">res 0,1 mm</span>).</p>
</li>
</ul>
<p data-path-to-node="7,23">La prova di carico statico ha dato esito positivo, confermando la sicurezza strutturale ed idoneità all&#8217;uso del soppalco.</p>
<h3 data-path-to-node="7,25">5. Normativa di Riferimento</h3>
<ul data-path-to-node="7,26">
<li>
<p data-path-to-node="7,26,0,0"><b data-path-to-node="7,26,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="7,26,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico e prove di carico sulle strutture metalliche</i>;</p>
</li>
<li>
<p data-path-to-node="7,26,1,0"><b data-path-to-node="7,26,1,0" data-index-in-node="0">Circolare Applicativa n. 7/2019:</b> <i data-path-to-node="7,26,1,0" data-index-in-node="33">Istruzioni per l&#8217;esecuzione dei collaudi statici di solai e soppalchi</i>;</p>
</li>
<li>
<p data-path-to-node="7,26,2,0"><b data-path-to-node="7,26,2,0" data-index-in-node="0">UNI EN 1993-1-1 (Eurocodice 3):</b> <i data-path-to-node="7,26,2,0" data-index-in-node="32">Progettazione delle strutture di acciaio &#8211; Regole generali e regole per gli edifici</i>.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/07/Particolare-del-contrasto.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Particolare-del-contrasto-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Contrasto della carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Particolare-del-contrasto-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/07/Particolare-del-contrasto-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/07/Martinetto-idraulico-a-spinta.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Martinetto-idraulico-a-spinta-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico su struttura in UPN" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Martinetto-idraulico-a-spinta-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/07/Martinetto-idraulico-a-spinta-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/07/Insieme-di-prova.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Insieme-di-prova-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico su struttura in acciaio" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/07/Insieme-di-prova-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/07/Insieme-di-prova-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-su-un-soppalco/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">80</post-id>	</item>
		<item>
		<title>Prova di Carico Statico di Verifica su Portale di Sostegno per Pensili Portastrumenti in Sala Risvegli</title>
		<link>https://www.structuralsurveys.it/lavori/verifica-statica-di-tre-pensili-portastrumenti/</link>
					<comments>https://www.structuralsurveys.it/lavori/verifica-statica-di-tre-pensili-portastrumenti/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Wed, 29 May 2013 14:56:25 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/03/yamaha-2017-motogp-bike-launched-with-rossi-and-vinales/</guid>

					<description><![CDATA[La struttura controllata era costituita da un ”portale a carpenteria metallica” che sostiene tre pensili portastrumenti, ciascun pensile è costituito da un braccio inclinato alla cui estremità e posizionato un piano che garantisce la portata massima di 80 Kg per la strumentazione da installare.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="7,3">1. Inquadramento Generale e Scopo delle Prove</h3>
<p data-path-to-node="7,4">In data 29 maggio 2013, su incarico dell&#8217;Azienda Ospedaliera di Padova e su indicazione della Direzione Lavori, è stata eseguita una prova di carico statico di verifica e collaudo sul portale di ancoraggio a soffitto destinato al sostegno di n. 3 pensili portastrumenti all&#8217;interno della nuova sala risvegli (<i data-path-to-node="7,4" data-index-in-node="309">Recovery Room</i>).</p>
<p data-path-to-node="7,5">Le indagini sperimentali sono state condotte da tecnici sperimentatori qualificati e certificati da RINA S.p.A. (Organismo Accreditato ACCREDIA) come Esperti di <span class="math-inline" data-math="III^\circ" data-index-in-node="161">III°</span> Livello per l&#8217;esecuzione di prove non distruttive e collaudi su strutture in c.a., c.a.p., muratura e carpenteria metallica (UNI EN ISO 9712).</p>
<h3 data-path-to-node="7,7">2. Schema Strutturale dell&#8217;Ancoraggio e Carichi di Prova</h3>
<p data-path-to-node="7,8">La struttura controllata è costituita da un portale primario in carpenteria metallica fisso a soffitto/solaio superiore, posto al di sopra della quota del controsoffitto modulare ispezionabile. Tale portale sostiene n. 3 bracci braccetti e colonne sospese articolate:</p>
<ul data-path-to-node="7,9">
<li>
<p data-path-to-node="7,9,0,0"><b data-path-to-node="7,9,0,0" data-index-in-node="0">Capacità portante nominale di progetto:</b> <span class="math-inline" data-math="80\text{ kg}" data-index-in-node="40">80 kg</span> per ciascun piano/piattaforma di lavoro del pensile;</p>
</li>
<li>
<p data-path-to-node="7,9,1,0"><b data-path-to-node="7,9,1,0" data-index-in-node="0">Over-strength di sicurezza (costruttore):</b> Incremento dinamico/strutturale pari al <span class="math-inline" data-math="+25\%" data-index-in-node="82">+25%</span>.</p>
</li>
</ul>
<p data-path-to-node="7,10">Per collaudare il portale sotto il massimo stress di esercizio previsto dalle schede tecniche della casa costruttrice, il carico statico di prova per ciascun pensile è stato fissato a <span class="math-inline" data-math="100\text{ kg}" data-index-in-node="184">100 kg</span> (<span class="math-inline" data-math="1{,}0\text{ kN}" data-index-in-node="199">1,0 kN)</span>, corrispondente al carico nominale maggiorato del <span class="math-inline" data-math="25\%" data-index-in-node="266">25%</span>.</p>
<p data-path-to-node="7,11"><b data-path-to-node="7,11" data-index-in-node="0">Modalità di zavorramento:</b> Il carico è stato applicato sulle piastre di estremità dei bracci impiegando sacchi di materiale edile a peso titolato e calibrato.</p>
<h3 data-path-to-node="7,13">3. Setup Sperimentale e Catena di Misura</h3>
<p data-path-to-node="7,14">Per consentire il posizionamento dei sensori di misura direttamente sugli elementi strutturali resistenti (senza interferenze con le finiture):</p>
<ol start="1" data-path-to-node="7,15">
<li>
<p data-path-to-node="7,15,0,0">Si è proceduto alla temporanea rimozione dei pannelli del controsoffitto in corrispondenza degli appoggi del portale e dei nodi di attacco delle piastre di sospensione;</p>
</li>
<li>
<p data-path-to-node="7,15,1,0">Sono stati posizionati trasduttori induttivi di spostamento (LVDT) ad alta precisione ancorati a caposaldi indipendenti per il monitoraggio continuativo delle frecce di inflessione e dei cedimenti dei vincoli a soffitto durante le fasi di applicazione e mantenimento del carico.</p>
</li>
</ol>
<h3 data-path-to-node="7,17">4. Esito della Prova e Giudizio di Idoneità</h3>
<p data-path-to-node="7,18">Durante la prova di carico statico, il comportamento del portale in carpenteria metallica ha evidenziato un&#8217;elevata rigidità flessionale e torsionale:</p>
<ul data-path-to-node="7,19">
<li>
<p data-path-to-node="7,19,0,0"><b data-path-to-node="7,19,0,0" data-index-in-node="0">Deformabilità massima:</b> I cedimenti verticali registrati dai trasduttori sono rimasti confinati all&#8217;interno del campo perfettamente elastico, con una freccia massima misurata non superiore al decimo di millimetro (<span class="math-inline" data-math="\delta_{max} \le 0{,}1\text{ mm}" data-index-in-node="213">δmax 0,1 mm</span>);</p>
</li>
<li>
<p data-path-to-node="7,19,1,0"><b data-path-to-node="7,19,1,0" data-index-in-node="0">Rientro Elastico:</b> Allo scarico completo dei pesi, si è assistito al totale azzeramento della deformazione residua.</p>
</li>
</ul>
<p data-path-to-node="7,20">La prova di carico ha pertanto dato esito positivo, confermando l&#8217;idoneità statica e la perfetta sicurezza d&#8217;uso dei pensili portastrumenti della sala risvegli.</p>
<h3 data-path-to-node="7,22">5. Normativa di Riferimento</h3>
<ul data-path-to-node="7,23">
<li>
<p data-path-to-node="7,23,0,0"><b data-path-to-node="7,23,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="7,23,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico ed esecuzione di prove di carico sulle strutture</i>;</p>
</li>
<li>
<p data-path-to-node="7,23,1,0"><b data-path-to-node="7,23,1,0" data-index-in-node="0">UNI EN 60601-1:</b> <i data-path-to-node="7,23,1,0" data-index-in-node="16">Apparecchiature elettromedicali &#8211; Parte 1: Prescrizioni generali relative alla sicurezza fondamentale e alle prestazioni essenziali (requisiti di stabilità e carico meccanico)</i>;</p>
</li>
<li>
<p data-path-to-node="7,23,2,0"><b data-path-to-node="7,23,2,0" data-index-in-node="0">HTM 02-01 / Linee Guida ISPESL:</b> <i data-path-to-node="7,23,2,0" data-index-in-node="32">Sicurezza delle installazioni a soffitto in ambiti chirurgici ed ospedalieri</i>.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Grafico-Carico-Cedimenti.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Grafico-Carico-Cedimenti-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Risultati sperimentali durante la prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Grafico-Carico-Cedimenti-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Grafico-Carico-Cedimenti-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-carichi.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-carichi-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico su pensili porta strumenti" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-carichi-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-carichi-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-scarichi.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-scarichi-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Ospedale di padova" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-scarichi-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Pensili-scarichi-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/verifica-statica-di-tre-pensili-portastrumenti/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">78</post-id>	</item>
		<item>
		<title>Prova di Carico Statico di Collaudo su Rampa di Scale in Calcestruzzo Armato</title>
		<link>https://www.structuralsurveys.it/lavori/prova-di-carico-su-rampa/</link>
					<comments>https://www.structuralsurveys.it/lavori/prova-di-carico-su-rampa/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Thu, 23 May 2013 14:56:41 +0000</pubDate>
				<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/01/31/this-chinese-province-says-it-faked-fiscal-data-for-several-years/</guid>

					<description><![CDATA[La prova di carico statica consente di misurare la capacità portante di un elemento strutturale. Nel caso in esame la struttura esaminata era una rampa di scale in calcestruzzo armato di un edificio di civile abitazione.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="6,3">1. Inquadramento dell&#8217;Edificio e Scopo della Prova</h3>
<p data-path-to-node="6,4">La prova di carico statico rappresenta il principale strumento diagnostico in situ per verificare la capacità portante e il comportamento deformativo effettivo di un elemento strutturale rispetto alle ipotesi teoriche di progetto. Nel caso in esame, la struttura oggetto di collaudo è costituita da una rampa di scale in calcestruzzo armato appartenente a un edificio a destinazione residenziale.</p>
<p data-path-to-node="6,5">Su indicazione della Committenza e della Direzione Lavori, è stata richiesta la verifica sperimentale della rampa per un carico utile distribuito di progetto pari a <span class="math-inline" data-math="q = 400\text{ kg/m}^2" data-index-in-node="165">q = 400 kg/m²</span> (<span class="math-inline" data-math="4{,}0\text{ kN/m}^2" data-index-in-node="188">4,0 kN/m²</span>).</p>
<h3 data-path-to-node="6,7">2. Modello Teorico ed Equivalenza dello Schema di Carico</h3>
<p data-path-to-node="6,8">Per evitare la movimentazione di zavorre gravimetriche sui pianerottoli e lungo i vani scala, si è adottato un sistema di applicazione del carico concentrato equivalente mediante martinetto oleodinamico.</p>
<p data-path-to-node="6,9">Schematizzando la striscia unitaria della rampa rampante come una trave appoggiata-appoggiata agli estremi (su travi di pianerottolo/setti), l&#8217;equivalenza dello stato di sollecitazione in mezzeria si basa sull&#8217;uguaglianza del momento flettente massimo <span class="math-inline" data-math="M_{max}" data-index-in-node="252">Mmax</span>:</p>
<div data-path-to-node="6,10">
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-4520" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/momento-removebg-preview.png" alt="" width="239" height="56" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/momento-removebg-preview.png 435w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/momento-removebg-preview-300x70.png 300w" sizes="(max-width: 239px) 100vw, 239px" /></p>
<div class="math-block" data-math="M_{mezzeria} = \frac{q \cdot L^2}{8} = \frac{P \cdot L}{4}">Dove:</div>
</div>
<ul data-path-to-node="6,12">
<li>
<p data-path-to-node="6,12,0,0"><b data-path-to-node="6,12,0,0" data-index-in-node="0"><span class="math-inline" data-math="q" data-index-in-node="0">q</span></b> = Carico distribuito di progetto (<span class="math-inline" data-math="4{,}0\text{ kN/m}^2" data-index-in-node="36">4,0 kN/m²</span>);</p>
</li>
<li>
<p data-path-to-node="6,12,1,0"><b data-path-to-node="6,12,1,0" data-index-in-node="0"><span class="math-inline" data-math="L" data-index-in-node="0">L</span></b> = Luce della rampa;</p>
</li>
<li>
<p data-path-to-node="6,12,2,0"><b data-path-to-node="6,12,2,0" data-index-in-node="0"><span class="math-inline" data-math="P" data-index-in-node="0">P</span></b> = Forza concentrata equivalente applicata in mezzeria dal martinetto (<span class="math-inline" data-math="\text{kN}" data-index-in-node="72">kN</span>).</p>
</li>
</ul>
<p data-path-to-node="6,13">Tenendo conto della collaborazione trasversale della soletta in c.a., la forza concentrata massima da applicare in mezzeria è risultata pari a <span class="math-inline" data-math="P_{max} \approx 4{,}0\text{ t}" data-index-in-node="143">Pmax 4,0 t</span> (<span class="math-inline" data-math="\approx 40\text{ kN}" data-index-in-node="175">40 kN</span>).</p>
<h3 data-path-to-node="6,15">3. Setup Sperimentale e Catena di Misura</h3>
<h4 data-path-to-node="6,16">A. Sistema Oleodinamico di Sollecitazione</h4>
<p data-path-to-node="6,17">Per l&#8217;applicazione controllata della spinta sono stati impiegati:</p>
<ul data-path-to-node="6,18">
<li>
<p data-path-to-node="6,18,0,0">Martinetto oleodinamico a spinta con pompa idraulica manuale Enerpac;</p>
</li>
<li>
<p data-path-to-node="6,18,1,0">N. 2 piastre di ripartizione in acciaio per la omogenea distribuzione delle tensioni locali sui lembi di calcestruzzo;</p>
</li>
<li>
<p data-path-to-node="6,18,2,0">Sistema di contrasto costituito da catene ad alta resistenza/tiranti di vincolo;</p>
</li>
<li>
<p data-path-to-node="6,18,3,0">Trasduttore di pressione / Cella di carico installato in serie al circuito idraulico del martinetto per la misurazione continua e rigorosa della forza impressa ad ogni step.</p>
</li>
</ul>
<h4 data-path-to-node="6,19">B. Protocollo di Prova e Sensori di Spostamento</h4>
<p data-path-to-node="6,20">La linearità della risposta deformativa ed il valore dei cedimenti residui sono stati valutati eseguendo n. 2 cicli completi di carico-scarico, suddivisi ciascuno in 4 step incrementali pari al <span class="math-inline" data-math="25\%" data-index-in-node="194">25%</span>, <span class="math-inline" data-math="50\%" data-index-in-node="200">50%</span>, <span class="math-inline" data-math="75\%" data-index-in-node="206">75%</span> e <span class="math-inline" data-math="100\%" data-index-in-node="213">100%</span> del carico massimo di prova.</p>
<p data-path-to-node="6,21">Il monitoraggio delle frecce d&#8217;abbassamento è stato effettuato mediante trasduttori induttivi di spostamento (LVDT) ad alta precisione posizionati in mezzeria e agli appoggi.</p>
<h3 data-path-to-node="6,23">4. Risultati Sperimentali</h3>
<ul data-path-to-node="6,24">
<li>
<p data-path-to-node="6,24,0,0"><b data-path-to-node="6,24,0,0" data-index-in-node="0">Comportamento Deformativo:</b> Sotto il carico massimo di <span class="math-inline" data-math="4{,}0\text{ t}" data-index-in-node="54">4,0 t</span>, le frecce d&#8217;abbassamento misurate al centro della rampa si sono mantenute nettamente al di sotto del valore soglia prescrittivo, con uno spostamento massimo registrato <span class="math-inline" data-math="\delta_{max} &lt; 0{,}7\text{ mm}" data-index-in-node="238">δ&lt; 0,7 mm</span>;</p>
</li>
<li>
<p data-path-to-node="6,24,1,0"><b data-path-to-node="6,24,1,0" data-index-in-node="0">Linearità e Rientro Elastico:</b> I diagrammi carico-deformazione hanno evidenziato un comportamento perfettamente lineare nel corso dei due cicli, con il completo annullamento dei cedimenti residue allo scarico.</p>
</li>
</ul>
<p data-path-to-node="6,25">La prova di carico statico ha pertanto dato esito positivo, confermando la piena idoneità statica e la sicurezza d&#8217;esercizio della rampa di scale in c.a.</p>
<h3 data-path-to-node="6,27">5. Normativa di Riferimento</h3>
<ul data-path-to-node="6,28">
<li>
<p data-path-to-node="6,28,0,0"><b data-path-to-node="6,28,0,0" data-index-in-node="0">NTC 2018 (D.M. 17 Gennaio 2018):</b> <i data-path-to-node="6,28,0,0" data-index-in-node="33">Capitolo 9 – Collaudo statico e prove di carico sulle strutture in c.a.</i>;</p>
</li>
<li>
<p data-path-to-node="6,28,1,0"><b data-path-to-node="6,28,1,0" data-index-in-node="0">Circolare Applicativa n. 7/2019:</b> <i data-path-to-node="6,28,1,0" data-index-in-node="33">Istruzioni per l&#8217;esecuzione dei collaudi statici di solai e scale</i>;</p>
</li>
<li>
<p data-path-to-node="6,28,2,0"><b data-path-to-node="6,28,2,0" data-index-in-node="0">UNI 10838:</b> <i data-path-to-node="6,28,2,0" data-index-in-node="11">Edilizia &#8211; Terminologia e classificazione dei controlli sulle strutture destinate alle costruzioni</i>.</p>
</li>
</ul>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Insieme-di-prova.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Insieme-di-prova-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Prova di carico su rampa di scale" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Insieme-di-prova-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Insieme-di-prova-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Piastra-di-contrasto.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Piastra-di-contrasto-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Particolare del contrasto per applicazione del carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Piastra-di-contrasto-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Piastra-di-contrasto-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/05/Trasduttori-di-posizione.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Trasduttori-di-posizione-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Flessimetri per misurare le deformazioni" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/05/Trasduttori-di-posizione-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/05/Trasduttori-di-posizione-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/prova-di-carico-su-rampa/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">81</post-id>	</item>
		<item>
		<title>Centosei Anni di Storia: Prova di Carico e Termografia al Complesso ai Colli</title>
		<link>https://www.structuralsurveys.it/lavori/indagine-termografica/prova-di-carico-su-solaio/</link>
					<comments>https://www.structuralsurveys.it/lavori/indagine-termografica/prova-di-carico-su-solaio/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Tue, 26 Feb 2013 15:56:19 +0000</pubDate>
				<category><![CDATA[Indagine Termografica]]></category>
		<category><![CDATA[Lavori]]></category>
		<category><![CDATA[Prova di carico]]></category>
		<category><![CDATA[prova di carico]]></category>
		<category><![CDATA[termografia]]></category>
		<guid isPermaLink="false">http://localhost/jnews/2019/02/04/sony-shares-a-list-of-39-titles-that-will-be-optimized-for-the-ps4-pro-at-launch/</guid>

					<description><![CDATA[Il Complesso Socio Sanitario ai Colli (ex Ospedale Psichiatrico) è collocato all'interno di un area caratterizzata dall'ampio parco e dalla struttura a padiglioni ampi. L'ospedale è stato progettato dall'ing. Francesco Sansoni e fu inaugurato il 16 giugno 1907.]]></description>
										<content:encoded><![CDATA[<h3 data-path-to-node="6,3">1. Inquadramento Storico e Strutturale</h3>
<p data-path-to-node="6,5">Su incarico dell’Azienda Ospedaliera di Padova, sono state eseguite indagini diagnostiche presso la Palazzina n. 6 (locale ex biblioteca) che hanno compreso:</p>
<ul data-path-to-node="6,6">
<li>
<p data-path-to-node="6,6,0,0">Una prova di carico statico su una porzione del solaio del primo piano;</p>
</li>
<li>
<p data-path-to-node="6,6,1,0">Indagini termografiche all&#8217;infrarosso sul soffitto per l&#8217;individuazione di infiltrazioni e difetti di impermeabilizzazione della copertura.</p>
</li>
</ul>
<h3 data-path-to-node="6,8">2. Prova di Carico Statico sul Solaio</h3>
<p data-path-to-node="6,9">L&#8217;indagine ha riguardato la verifica della risposta statica di una campata di solaio al primo piano, avente una luce netta di calcolo pari a <span class="math-inline" data-math="8,00\text{ m}" data-index-in-node="141">8,00 m</span>, sotto un carico di progetto equivalente pari a <span class="math-inline" data-math="600\text{ kg/m}^2" data-index-in-node="203">600 kg/m²</span> (<span class="math-inline" data-math="6,00\text{ kN/m}^2" data-index-in-node="222">6,00 kN/m²</span>).</p>
<ul data-path-to-node="6,10">
<li>
<p data-path-to-node="6,10,0,0"><b data-path-to-node="6,10,0,0" data-index-in-node="0">Schema di sollecitazione e contrasto:</b> Per indurre momenti flettenti equivalenti al carico distribuito senza sovraccaricare la struttura con zavorre fisse, è stata applicata una forza concentrata in mezzeria tramite un martinetto oleodinamico a tiro Enerpac.</p>
</li>
<li>
<p data-path-to-node="6,10,1,0"><b data-path-to-node="6,10,1,0" data-index-in-node="0">Ripartizione e misura del carico:</b> In corrispondenza del punto di applicazione del tiro è stata posizionata una trave/putrella d&#8217;acciaio della lunghezza di <span class="math-inline" data-math="1,00\text{ m}" data-index-in-node="155">1,00 m</span> per ripartire lo sforzo. La forza applicata è stata misurata in continuo mediante due trasduttori di pressione montati in serie alla centralina oleodinamica.</p>
</li>
<li>
<p data-path-to-node="6,10,2,0"><b data-path-to-node="6,10,2,0" data-index-in-node="0">Strumentazione di misura dei cedimenti:</b> Per tracciare la linea elastica, sono stati posizionati <span class="math-inline" data-math="6" data-index-in-node="96">6</span> trasduttori di spostamento (LVDT/potenziometrici) distribuiti secondo il seguente schema:</p>
<ul data-path-to-node="6,10,2,1">
<li>
<p data-path-to-node="6,10,2,1,0,0"><span class="math-inline" data-math="2" data-index-in-node="0">2</span> trasduttori in corrispondenza degli appoggi;</p>
</li>
<li>
<p data-path-to-node="6,10,2,1,1,0"><span class="math-inline" data-math="1" data-index-in-node="0">1</span> trasduttore nel punto di tiro (mezzeria);</p>
</li>
<li>
<p data-path-to-node="6,10,2,1,2,0"><span class="math-inline" data-math="3" data-index-in-node="0">3</span> trasduttori posti a <span class="math-inline" data-math="1,00\text{ m}" data-index-in-node="22">1,00 m</span> e <span class="math-inline" data-math="2,00\text{ m}" data-index-in-node="38">2,00 m</span> di distanza dalla mezzeria per valutare la collaborazione trasversale.</p>
</li>
</ul>
</li>
</ul>
<p data-path-to-node="6,11"><b data-path-to-node="6,11" data-index-in-node="0">Esito della prova:</b> Nonostante i suoi 106 anni di vita utile, il solaio ha evidenziato un comportamento perfettamente elastico e lineare, registrando una deformazione massima residua trascurabile e una freccia massima in mezzeria contenuta entro circa <span class="math-inline" data-math="0,7\text{ mm}" data-index-in-node="251">0,7 mm</span>.</p>
<h3 data-path-to-node="6,13">3. Indagine Termografica (IRT)</h3>
<p data-path-to-node="6,14">L’ispezione termografica eseguita sull&#8217;intradosso del soffitto del primo piano ha evidenziato due zone circoscritte caratterizzate da un&#8217;anomalia termica fredda marcata, sintomo di un elevato contenuto di umidità nell&#8217;estradosso.</p>
<p data-path-to-node="6,15">Tale riscontro conferma la presenza di discontinuità e difetti di tenuta nel manto d&#8217;impermeabilizzazione della copertura del tetto sovrastante.</p>

<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/02/Locale-ex-biblioteca.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Locale-ex-biblioteca-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Solaio in calcestruzzo armato" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Locale-ex-biblioteca-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/02/Locale-ex-biblioteca-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/02/Insieme-di-Prova.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Insieme-di-Prova-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Esecuzione di una prova di carico con carco concentrato" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Insieme-di-Prova-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/02/Insieme-di-Prova-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/02/Grafico-Carico-Cedimenti.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Grafico-Carico-Cedimenti-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Grafico Prova di carico" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Grafico-Carico-Cedimenti-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/02/Grafico-Carico-Cedimenti-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>
<a href='https://www.structuralsurveys.it/wp-content/uploads/2013/02/Indagine-termografica.jpg'><img loading="lazy" decoding="async" width="150" height="150" src="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Indagine-termografica-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="Infiltrazioni d&#039;acqua" srcset="https://www.structuralsurveys.it/wp-content/uploads/2013/02/Indagine-termografica-150x150.jpg 150w, https://www.structuralsurveys.it/wp-content/uploads/2013/02/Indagine-termografica-100x100.jpg 100w" sizes="(max-width: 150px) 100vw, 150px" /></a>

]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/lavori/indagine-termografica/prova-di-carico-su-solaio/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">77</post-id>	</item>
	</channel>