<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>flaw detector &#8211; Indagini strutturali</title>
	<atom:link href="https://www.structuralsurveys.it/tag-prodotto/flaw-detector/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.structuralsurveys.it</link>
	<description>Diagnostica e monitoraggio del costruito</description>
	<lastBuildDate>Fri, 20 May 2022 16:35:49 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://www.structuralsurveys.it/wp-content/uploads/2019/12/cropped-favicon-32x32.png</url>
	<title>flaw detector &#8211; Indagini strutturali</title>
	<link>https://www.structuralsurveys.it</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">170619051</site>	<item>
		<title>Rilevatore di difetti UD-3701</title>
		<link>https://www.structuralsurveys.it/negozio/rilievo-di-difetti-e-spessori/ud-3701/</link>
					<comments>https://www.structuralsurveys.it/negozio/rilievo-di-difetti-e-spessori/ud-3701/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Mon, 22 Jul 2019 13:17:41 +0000</pubDate>
				<guid isPermaLink="false">http://www.structuralsurveys.it/?post_type=product&#038;p=1576</guid>

					<description><![CDATA[Il rilevatore di difetti ad ultrasuoni NOVOTEST UD3701 è progettato per rilevare difetti, quali discontinuità ed eterogeneità negli oggetti, qualità dei giunti saldati, per misurare la profondità e la posizione di difetti, misure di spessore, misure di velocità e attenuazione di onde ultrasoniche per diversi materiali.]]></description>
										<content:encoded><![CDATA[<p>Lo strumento UD3701 dispone di un ampio display touchscreen da 7 pollici e involucro metallico potente, leggero, portatile ed ergonomico, ed è la scelta migliore per i test ad ultrasuoni esperti. Il rilevatore di difetti ad ultrasuoni NOVOTEST UD3701 consente all&#8217;utente di misurare lo spessore dei prodotti con elevata accuratezza, il segnale può essere visualizzato sotto forma di scansione A e scansione B e ha tutte le caratteristiche della documentazione di prova completa.</p>
<h4>Specifiche tecniche</h4>
<p>The range of measured depth (steel), mm 6000<br />
The range of gain control 100 dB in 0.1 dB<br />
Temporary adjustment of gain (TCG) range up to 70 dB, with the construction of the curve with 32 control points entered manually or from the control reflectors<br />
The control zone two independent zones, start and change the width of the entire range of sweep<br />
Interrogator customizable, with an amplitude of 350 V, with a variable length from 12.5 to 500 ns, 12.5 ns increments<br />
Memory configuration with A-scan (B-scans), limited the size of SD-card<br />
control protocols (signal envelope, the measurement, the parameters of the device, date, time and name of the protocol), limited the size of SD-card<br />
Interface Bluetooth, SD-card<br />
Detailed specifications of Ultrasonic Flaw Detector NOVOTEST UD3701<br />
Scan<br />
min .: 0 – 6 μs<br />
max .: 0 – 1000 μs<br />
step – 25 ns</p>
<p>Exposition<br />
from 0 μs to 1000 μs<br />
step – 25 ns</p>
<p>MAX length of tested material<br />
up to 6000 mm (echo mode)</p>
<p>Velocity range<br />
1000 – 9999 m/s</p>
<p>Exposition in the prism<br />
0 – 100 μs<br />
step – 25 ns</p>
<p>Damping<br />
50 Ohm</p>
<p>Input impedance<br />
50 Ohm / 600 Ohm</p>
<p>Probes pulse<br />
RF pulse with amplitude of 100, 200 or 300V,<br />
With variable length from 25 to 500 ns,<br />
step – 25 ns</p>
<p>Repetition frequency of SP<br />
automatically controlled from 10 to 100Hz</p>
<p>Amplifier<br />
Wideband 0.4-20 MHz (-6 dB)</p>
<p>Gain control range<br />
115 dB, step – 1 dB</p>
<p>Time control gain (TCG)<br />
range up to 70 dB, 12 dB / μs<br />
with the construction of the curve through 16 reference points,<br />
entered by hand or by the control reflectors</p>
<p>Amplitude-Distance curve<br />
drawing through 16 points, height adjustable</p>
<p>Detection<br />
positive or negative half-wave,<br />
complete, the radio signal (at all range of scan), B-scan</p>
<p>Cutoff<br />
compensated, 0 – 90% of screen height</p>
<p>Zone control<br />
two independents areas, the beginning and width are change at all scan range; levels of limits are set from 0 to 100% of display height; individual logic of detection defects.</p>
<p>Automatic Alarm of defects<br />
light logic of detection defect in zone for each zone individually and sound individual logic detection defect at the zone</p>
<p>Time intervals measurement<br />
from 0 to a first signal in the zone or between<br />
signals in the zones to the front or to the maximum signal</p>
<p>Measurement of amplitude<br />
in dB relative to threshold level in the zone;<br />
in dB relative to the reference signal;<br />
in dB relative to the amplitude-distance curve.</p>
<p>Display<br />
Colored, TFT 320 x 240 pixels 135 x 100 mm.</p>
<p>Memory<br />
Limited of SD cards capacity</p>
<p>Interface<br />
USB, Bluetooth (optional)</p>
<p>Connectors of probes<br />
2 Lemo</p>
<p>Battery<br />
Li-on 4-7 a / h</p>
<p>Battery life<br />
up to 10 hours with the battery 4000 a / h<br />
up to 24 hours with the battery 6600 a / h (optional)</p>
<p>External power supply<br />
power supply 220V, 50Hz AC</p>
<p>Supply voltage<br />
15V 2A</p>
<p>Operating temperature range<br />
from -30º C to + 55 ° C</p>
<p>Dimensions (H x W x L)<br />
140 mm x 210 mm x 55 mm with standard battery (4000 a / h)<br />
140 mm x 210 mm x 85 mm with the battery 6600 a / h (optional)</p>
<p>Weight<br />
1.7 kg with standard battery (4000 a / h)<br />
2.7 kg with battery 6600 a / h (option)</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.structuralsurveys.it/negozio/rilievo-di-difetti-e-spessori/ud-3701/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1576</post-id>	</item>
		<item>
		<title>Rilevatore di difetti UD-2301</title>
		<link>https://www.structuralsurveys.it/negozio/rilievo-di-difetti-e-spessori/ud-2301/</link>
					<comments>https://www.structuralsurveys.it/negozio/rilievo-di-difetti-e-spessori/ud-2301/#respond</comments>
		
		<dc:creator><![CDATA[Erion Lako]]></dc:creator>
		<pubDate>Sun, 21 Jul 2019 21:42:29 +0000</pubDate>
				<guid isPermaLink="false">http://www.structuralsurveys.it/?post_type=product&#038;p=1565</guid>

					<description><![CDATA[Il rilevatore di difetti ad ultrasuoni UD2301-mini è progettato per test non distruttivi su metalli, plastica, vetro, materiali compositi, ispezione di saldatura e misurazione dello spessore dei vari prodotti e strutture.]]></description>
										<content:encoded><![CDATA[<p>L&#8217;UD-2301 consente all&#8217;utente di rilevare vari difetti quali discontinuità, crepe ed eterogeneità dei materiali nei prodotti semifiniti e giunti saldati, per misurare la profondità e le coordinate dei difetti, lo spessore dei prodotti, la velocità di propagazione e l&#8217;attenuazione delle vibrazioni ultrasoniche (UT) nel materiale.<br />
Il rilevatore di difetti ad ultrasuoni viene prodotto in un piccolo alloggiamento di dimensioni ottimali per eseguire test in spazi ristretti. Il dispositivo ha un display a colori ad alta risoluzione (320 * 480 pixel), che ne migliora notevolmente l&#8217;usabilità.</p>
<h4>Specifiche tecniche</h4>
<p>Operating frequency range from 1 to 10,0 MHz;<br />
Range of measured time intervals (duration of scanning) from 6 to 1000 µs;<br />
Velocity range 1000 – 9999 m / s;<br />
Error of measurement of time intervals not exceed ± 0,025 µs;<br />
Maximum permissible error of measurement of the amplitudes of the signals at the receiver input in the range from 0 to 110 dB not exceed ± 0,5 dB;<br />
Testing gain range 125 dB;<br />
Averaging over the quantity of starts from 1 to 16;<br />
Range of variation of temporal sensitivity adjustment (TVG) 40 dB;<br />
Number of control points TVG 15;<br />
Duration of the excitation pulse to the load from 0,0 to 0,5 µs;<br />
Amplitude of the excitation pulse to the 50 Ohm load, not less 100, 200, 300;<br />
Operating frequency range of the receiver on the level -3 dB from 1 to 10 MHz;<br />
Deviation of the amplitudes of input signals in the range from 10 to 100% of the screen height not more than 1 dB;<br />
Scanning from 1 to 1000 µs;<br />
Delay of scanning from 0 to 2000 µs;<br />
Range of measurement of time intervals from 0 to 1000 µs;<br />
Setting a delay in the prism of the probe from 0 to 15 µs ;<br />
Automatic signaling of defects (AFS) dual-gate;<br />
Setting range of AFS gates from 0 to 2000 µs;<br />
Adjusting thresholds of AFS gates from 0 to 100 % of screen height;<br />
Detection of signals positive half-wave, radio mode;<br />
Dimensions (W*H*L) 80*162*38 mm;<br />
Weight, not more 250 g (without batteries);<br />
Mean time between failures not less than – 3000 hours.</p>